Precision Motion Systems
Connecting electromechanical models, digital control and vibration analysis to improve a flexure-guided positioning axis.
- Precision positioning
- Model-based control
- Vibration analysis
- Experimental identification
Conceptual single-axis mechanism, not a CAD reconstruction or a measured response.
Overview
Precision motion is not just a controller-tuning problem. The actuator, flexible mechanism, sensor and digital implementation all shape the motion that can actually be achieved. This work connected those layers in a linear-motor positioning system developed at SUPSI-ISEA.
The wider platform used a parallel-kinematic arrangement. The detailed investigation focused on a single flexure-guided axis, isolating the electrical dynamics, structural modes and measurement effects that limited its control bandwidth. The investigation is documented in the 2019 test campaign.
My contribution
I worked on electromechanical modelling, parameter identification, position and current control, vibration analysis and experimental testing. I also developed C control algorithms and supporting tools for configuration, communication and data processing.
My main contribution connected the model and the physical system: using measurements to identify missing dynamics, then evaluating algorithmic and mechanical improvements within the wider team.
Challenge
Flexures enable fine motion without conventional sliding guides, but their structural modes become part of the control problem. Increasing feedback gain can excite those modes, while sensor noise, filter delay and actuator saturation further constrain the usable bandwidth.
The task was to establish which limitation came from the plant, which came from the controller, and which came from the measurement itself. That distinction determines whether to change a model, an algorithm, a filter or the structure.
Approach
Start with coupled dynamics, then identify what is missing
A first model coupled the actuator winding to the moving mass and flexure stiffness:
Here, voltage produces current and actuator force, while motion feeds back through the back electromotive force. Identification addressed electrical parameters, stiffness, damping and the position dependence of the actuator force constant. Flexible-body modes were then added where the low-order model no longer described the measured behaviour.


Use three complementary views of the structure
Experimental modal analysis identified resonances and mode shapes; finite-element analysis helped locate the corresponding deformation; operating frequency-response measurements showed how those dynamics entered the controlled axis.
The instrumentation mattered too. An accelerometer can load a light flexure and change the dynamics it is intended to measure. Local measurements with a lighter sensor supported the interpretation of a high-frequency flexure-blade mode propagating into the moving assembly.
Implementation
The control architecture separated mechanical position regulation from electrical current regulation. Position and velocity feedback, with integral action, generated a current command. The current-control stage included model-based feedforward and back-EMF compensation.
The C implementations handled current and voltage limits explicitly, including anti-windup feedback. Observer work examined floating-point behaviour when very small position changes coexist with much larger coordinates; one implementation represented a local position correction relative to the encoder measurement.

Host-side tools supported excitation configuration, acquisition, repeated measurements and frequency-domain processing. Communication work included EtherCAT device-description and process-data configuration. These tools connected controller development with repeatable experimental evaluation.
Results
Connect control improvements to physical evidence
The principal control report describes an increase in usable bandwidth from approximately 50 Hz to 230 Hz following identification and control improvements. Separately, five measured/FEM modal-frequency pairs agreed within a maximum relative frequency difference of 7.70%.
Documented single-axis work · 2019
- Reported control-bandwidth improvement
- ≈50 → 230 Hz
Principal control report · documented axis and configuration
- Largest modal-frequency difference
- 7.70%
Experimental modal analysis vs FEM · five compared modes
Experimental and FEM modal frequencies
ExperimentalFinite-element model
Mode 2
Mode 3
Mode 4
Mode 5
Shared linear bar scale: 0–1800 Hz
View all five modal-frequency comparisons
| Comparison mode | Experimental | FEM | Relative difference |
|---|---|---|---|
| 1 | 10 Hz | 10 Hz | 0.00% |
| 2 | 550 Hz | 514 Hz | 6.55% |
| 3 | 798 Hz | 811 Hz | 1.63% |
| 4 | 974 Hz | 1049 Hz | 7.70% |
| 5 | 1586 Hz | 1511 Hz | 4.73% |
Relative difference = 100 × |experimental − FEM| / experimental. Comparison-mode numbers follow the report table, not the FEM software's internal numbering.
Separate step-test campaign: 25 µm steps · 20 measurements per setting · 130 / 150 / 200 Hz settings. No new acquisition or accuracy certification.
Frequency agreement supported the interpretation of the vibration modes; it did not establish matching damping or response amplitude. Selected physical damping modifications were measured, while input shaping, higher-order feedback and inertia-related compensation also included theoretical or simulation studies. No unverified attenuation percentage is assigned to those methods.
Validate the model against measurements
A measured position-to-current frequency response provided a second check on the mechanical model. The comparison below uses the saved complex response from the later single-axis identification campaign and the mass, damping, stiffness and actuator constant archived with it.
Agreement at low frequency supports the dominant mass–spring–damper representation. Higher-frequency departures reveal dynamics that the simple model does not capture.
From vibration analysis to structural improvement
The modal investigation also tested a physical intervention: adding an elastomer-and-aluminium damping layer to the flexure arms. Comparing the archived response at measurement point 4 before and after the modification makes its effect visible. The broadband view provides context; the detail isolates the resonance region.
The comparison supports a specific engineering conclusion: damping on the flexure changed both the resonance amplitude and its frequency. It does not imply uniform improvement at every frequency. Tests with damping at the flexure junction were a separate intervention and are not mixed into these two curves.
A later, separate performance campaign used 25 µm position steps, with 20 measurements per bandwidth setting at 130, 150 and 200 Hz. Those test settings remain distinct from both this modal comparison and the earlier reported bandwidth improvement.
Measurement notes
Bandwidth and absolute positioning accuracy describe different properties. Nanometre-scale positioning was a project objective; the results here concern the investigated single axis.
Each frequency-response curve retains its original measured frequency grid, without smoothing or alignment. Phase is wrapped to −270…90° without connecting across wraps. The damping comparison uses the stored dB scale; the model comparison is converted from encoder counts to m/A. The two campaigns and the later step-test settings remain distinct.
The engineering outcome was a more useful explanation of the system’s limits: measured dynamics informed the model, the model guided control changes, and vibration analysis identified where structural intervention could help. That workflow connects modelling, embedded implementation and experimental judgement rather than treating them as separate tasks.