Research / 07

2019

Precision Motion Systems

Connecting electromechanical models, digital control and vibration analysis to improve a flexure-guided positioning axis.

  • Precision positioning
  • Model-based control
  • Vibration analysis
  • Experimental identification
Conceptual flexure-guided axis with a fixed frame, suspended moving mass and blue linear actuator; not experimental evidence.

Conceptual single-axis mechanism, not a CAD reconstruction or a measured response.

Overview

Precision motion is not just a controller-tuning problem. The actuator, flexible mechanism, sensor and digital implementation all shape the motion that can actually be achieved. This work connected those layers in a linear-motor positioning system developed at SUPSI-ISEA.

The wider platform used a parallel-kinematic arrangement. The detailed investigation focused on a single flexure-guided axis, isolating the electrical dynamics, structural modes and measurement effects that limited its control bandwidth. The investigation is documented in the 2019 test campaign.

My contribution

I worked on electromechanical modelling, parameter identification, position and current control, vibration analysis and experimental testing. I also developed C control algorithms and supporting tools for configuration, communication and data processing.

My main contribution connected the model and the physical system: using measurements to identify missing dynamics, then evaluating algorithmic and mechanical improvements within the wider team.

Challenge

Flexures enable fine motion without conventional sliding guides, but their structural modes become part of the control problem. Increasing feedback gain can excite those modes, while sensor noise, filter delay and actuator saturation further constrain the usable bandwidth.

The task was to establish which limitation came from the plant, which came from the controller, and which came from the measurement itself. That distinction determines whether to change a model, an algorithm, a filter or the structure.

Approach

Start with coupled dynamics, then identify what is missing

A first model coupled the actuator winding to the moving mass and flexure stiffness:

Mx¨+cx˙+kx=Kti,Li˙+Ri+Kex˙=u.\begin{aligned} M\ddot{x} + c\dot{x} + kx &= K_t i, \\ L\dot{i} + Ri + K_e\dot{x} &= u. \end{aligned}

Here, voltage uu produces current ii and actuator force, while motion feeds back through the back electromotive force. Identification addressed electrical parameters, stiffness, damping and the position dependence of the actuator force constant. Flexible-body modes were then added where the low-order model no longer described the measured behaviour.

Original single-axis test assembly with a voice-coil actuator, moving mass and flexure-guided mechanism.
Single-axis experimental assembly with a voice-coil actuator and flexure guidance.
Finite-element mesh and mode-shape visualization of the flexure mechanism near 1511 Hz.
FEM visualization of a flexure mode near 1511 Hz.

Use three complementary views of the structure

Experimental modal analysis identified resonances and mode shapes; finite-element analysis helped locate the corresponding deformation; operating frequency-response measurements showed how those dynamics entered the controlled axis.

The instrumentation mattered too. An accelerometer can load a light flexure and change the dynamics it is intended to measure. Local measurements with a lighter sensor supported the interpretation of a high-frequency flexure-blade mode propagating into the moving assembly.

Implementation

The control architecture separated mechanical position regulation from electrical current regulation. Position and velocity feedback, with integral action, generated a current command. The current-control stage included model-based feedforward and back-EMF compensation.

The C implementations handled current and voltage limits explicitly, including anti-windup feedback. Observer work examined floating-point behaviour when very small position changes coexist with much larger coordinates; one implementation represented a local position correction relative to the encoder measurement.

Original mechanical position-controller model showing position and velocity feedback, integral action, current limiting and anti-windup feedback.
Position-control architecture with a bounded current reference and anti-windup.

Host-side tools supported excitation configuration, acquisition, repeated measurements and frequency-domain processing. Communication work included EtherCAT device-description and process-data configuration. These tools connected controller development with repeatable experimental evaluation.

Results

Connect control improvements to physical evidence

The principal control report describes an increase in usable bandwidth from approximately 50 Hz to 230 Hz following identification and control improvements. Separately, five measured/FEM modal-frequency pairs agreed within a maximum relative frequency difference of 7.70%.

Documented single-axis work · 2019

Reported control-bandwidth improvement
≈50 → 230 Hz

Principal control report · documented axis and configuration

Largest modal-frequency difference
7.70%

Experimental modal analysis vs FEM · five compared modes

Experimental and FEM modal frequencies

ExperimentalFinite-element model

Mode 2

550 Hz
514 Hz

Mode 3

798 Hz
811 Hz

Mode 4

974 Hz
1049 Hz

Mode 5

1586 Hz
1511 Hz

Shared linear bar scale: 0–1800 Hz

Four higher-frequency modes from the archived comparison. Solid blue bars denote experiment; outlined bars denote FEM. All bars start at zero. The 10 Hz mode and all exact values are in the table below. Frequency agreement does not establish matching damping or vibration amplitude.
View all five modal-frequency comparisons
Principal control report · table 8.1, p. 35
Comparison modeExperimentalFEMRelative difference
110 Hz10 Hz0.00%
2550 Hz514 Hz6.55%
3798 Hz811 Hz1.63%
4974 Hz1049 Hz7.70%
51586 Hz1511 Hz4.73%

Relative difference = 100 × |experimental − FEM| / experimental. Comparison-mode numbers follow the report table, not the FEM software's internal numbering.

Separate step-test campaign: 25 µm steps · 20 measurements per setting · 130 / 150 / 200 Hz settings. No new acquisition or accuracy certification.

Frequency agreement supported the interpretation of the vibration modes; it did not establish matching damping or response amplitude. Selected physical damping modifications were measured, while input shaping, higher-order feedback and inertia-related compensation also included theoretical or simulation studies. No unverified attenuation percentage is assigned to those methods.

Validate the model against measurements

A measured position-to-current frequency response provided a second check on the mechanical model. The comparison below uses the saved complex response from the later single-axis identification campaign and the mass, damping, stiffness and actuator constant archived with it.

Archived measured position-to-current response compared with a low-order mechanical model: magnitude agrees at low frequency and becomes more dispersed at high frequency; the second panel shows phase.
Measured response in blue; low-order model in dashed black. Magnitude is in dB relative to 1 m/A.

Agreement at low frequency supports the dominant mass–spring–damper representation. Higher-frequency departures reveal dynamics that the simple model does not capture.

From vibration analysis to structural improvement

The modal investigation also tested a physical intervention: adding an elastomer-and-aluminium damping layer to the flexure arms. Comparing the archived response at measurement point 4 before and after the modification makes its effect visible. The broadband view provides context; the detail isolates the resonance region.

Experimental modal-response magnitude at point 4 before and after flexure damping, with a broadband view and an enlarged 1100 to 2000 Hz detail showing an attenuated and shifted resonance.
Response at measurement point 4: baseline in dashed black, added flexure damping in blue. The detail highlights the resonance region.

The comparison supports a specific engineering conclusion: damping on the flexure changed both the resonance amplitude and its frequency. It does not imply uniform improvement at every frequency. Tests with damping at the flexure junction were a separate intervention and are not mixed into these two curves.

A later, separate performance campaign used 25 µm position steps, with 20 measurements per bandwidth setting at 130, 150 and 200 Hz. Those test settings remain distinct from both this modal comparison and the earlier reported bandwidth improvement.

Measurement notes

Bandwidth and absolute positioning accuracy describe different properties. Nanometre-scale positioning was a project objective; the results here concern the investigated single axis.

Each frequency-response curve retains its original measured frequency grid, without smoothing or alignment. Phase is wrapped to −270…90° without connecting across wraps. The damping comparison uses the stored dB scale; the model comparison is converted from encoder counts to m/A. The two campaigns and the later step-test settings remain distinct.

The engineering outcome was a more useful explanation of the system’s limits: measured dynamics informed the model, the model guided control changes, and vibration analysis identified where structural intervention could help. That workflow connects modelling, embedded implementation and experimental judgement rather than treating them as separate tasks.