Overview

The RPDIS project developed a mobile robotic approach to targeted indoor aerosol treatment. Rather than treating navigation coverage as a proxy for delivery, the work connected robot motion and spray orientation to a reduced physical model of the concentration distribution over time.

The central idea was to represent where the robot moves and where it directs treatment as separate paths, then synchronize them for execution. The work connected physical modelling, map-based planning, numerical optimization, Python software and experimental analysis.

My contribution

I worked on physical modelling, parameter identification, simulations, trajectory planning, optimization, control, software development and experimental testing. My contribution connected mathematical models with Python implementations, robotic execution and sensor-data analysis. The archived algorithm document and trajectory-generation module identify my authorship; the associated research preprint names me as first author.

The work was collaborative. Navigation, sensing and other subsystems also involved colleagues; the experimental results belong to the project team.

Challenge

A collision-free route does not determine how much aerosol reaches a target. Delivery also depends on spray direction, distance, application time and decay. Two geometrically similar routes can therefore produce different concentration distributions.

The planner combined an environment map with a selected target mask: a non-traversable object could remain a treatment target while the robot travelled around it. The target mask was a planning input; it was not itself a measurement of contamination.

Approach

Model and identify the application pattern

An anisotropic Gaussian kernel approximated the directional application footprint on the environment grid. An exponential decay approximation represented the reduction of concentration response over time. Measurements at known sensor positions informed pattern width, displacement and decay; a calibrated relationship connected fan command with the position of the pattern centre.

This reduced model made repeated planning evaluations practical. It was an experimentally informed approximation, with limitations from airflow, humidity, temperature and surface interactions, rather than a full fluid-dynamics model.

Original planning workflow from map and target definition through boundary construction, keypoint selection, trajectory generation and process evaluation.
From target selection to synchronized trajectories and process evaluation.Project algorithm documentation · 2025

Separate navigation from treatment

Offset boundaries accounted for robot clearance and useful spraying distances. A smooth enclosing path provided a navigation reference, while greedy footprint placement selected treatment keypoints over the target mask. A constrained travelling-salesman formulation ordered those selected points with specified endpoints.

Navigation position and treatment position were expressed as separate B-spline curves. Rescaling their parameter domains and inserting compatible knots allowed their coordinates to be combined into a synchronized representation. This preserved the difference between the robot’s position and its intended treatment target.

Original examples of treatment keypoints, ordered target paths and B-spline trajectories with full and partial enclosing navigation paths.
Treatment keypoints and smooth trajectories for complete and partial access routes.Project algorithm documentation · 2025

Evaluate trajectory and speed together

The process emulator accumulated the spatial kernel along the planned treatment path and evaluated the evolving concentration field. A binary-search routine selected execution speed against the configured coverage criterion. Optimization of the selected keypoint order did not establish global optimality of the complete treatment problem.

Original simulation frame showing navigation and treatment paths with the modelled aerosol concentration field.
Simulated aerosol accumulation used to evaluate trajectory and speed.Project algorithm documentation · Simulation

Software, sensing and practical integration

Python modules separated boundary construction, pattern placement, B-spline operations, aerosol emulation, automatic trajectory generation and experimental analysis. The broader system connected ROS 2 navigation and mapping with distributed concentration sensing and CSV logging.

Wireless sensors recorded concentration at known positions. Retained time series, sensor coordinates and robot trajectories connected each experiment to its planning context and supported spatial-response analysis.

Original CAD rendering of the wireless concentration-sensor enclosure.
CAD concept for the concentration-sensor enclosure in the distributed sensing system.Project sensor documentation · Team design

During execution, actual robot position could be projected onto the planned curve to determine the corresponding treatment target, spray direction and fan command. This position-based adaptation addressed pointing errors caused by navigation deviations. It should be distinguished from concentration-sensor feedback, which the associated preprint identifies as further work.

Results

Retained four-sensor trial

The archive retains four concentration channels, sensor positions, trajectory exports and a configured 50 ppm planning target. The chart below was reconstructed in the presentation package from the exported time series, retaining all samples without fitting.

Four measured concentration time series with a dashed line at the configured 50 ppm planning target.
Four measured concentration channels; the dashed line marks the 50 ppm planning target.Archived March 2025 trial · Reconstructed from exported measurements
SensorMaximum concentration
S151.99 ppm
S248.59 ppm
S356.19 ppm
S455.44 ppm

Across the four sensor maxima, the mean was 53.05 ppm, the population standard deviation 3.02 ppm and the coefficient of variation 5.70%, as independently reproduced in the supplied presentation package. These are separate maxima over time, rather than simultaneous concentration uniformity. Three of four sensors reached 50 ppm; S2 peaked below that target.

Research outcome

The associated preprint, version 1, reports concentration variability reduced from approximately 25% to 6%, nearly 50% shorter execution time and more than 40% lower disinfectant consumption in its studied comparison. These are publication-reported comparisons, not reductions recalculated from the single trial above.

Engineering takeaways

  • Physical modelling: retain the process effects needed for practical trajectory evaluation.
  • Coordinated planning: synchronize robot motion and treatment targets without conflating their geometry.
  • Implementation: connect numerical methods, robotic execution and traceable sensor records.
  • Experimental interpretation: distinguish simulated fields, individual trials and publication-level comparisons.

Sources